Create the Z500 account
Get full support

What to gain?

  • detailed drawings for the project
  • contact with users
  • construction sites in the area
  • special promotions
  • you can watch other builders
  • adding to favorites
Home project Zx108 NF40 - Wersja projektu w standardzie NF40

Zx108 NF40 mirror image

Wersja projektu w standardzie NF40
brick
brick
brick
brick
mirror image
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project Zx108 NF40 - Wersja projektu w standardzie NF40
Home project  - Wersja projektu w standardzie NF40

Ground 122,1 / 168,2

Sień
4,7 m²
Kuchnia+jadalnia
32,7 m²
Salon
35,8 m²
Hall+stairs
23,4 m²
Office
12,0 m²
Pom. gosp.
5,1 m²
Garage
46,1 m²
Łazienka
3,6 m²
Hall
2,1 m²
Spiżarka
2,8 m²
mirror
image
Draw

Click or touch on the image on the left to start the measure.
Draw sketch on image and click save icon.
Sketch has been sent.
Home project  - Wersja projektu w standardzie NF40

Floor 81,1

Hall
16,5 m²
Łazienka
10,8 m²
Pokój
13,5 m²
Pokój
13,3 m²
Wardrobe
3,9 m²
Wardrobe
5,2 m²
Łazienka
4,8 m²
Pokój
13,1 m²
mirror
image
Draw

Click or touch on the image on the left to start the measure.
Draw sketch on image and click save icon.
Sketch has been sent.
Home project  - Wersja projektu w standardzie NF40

Minimal plot - dimensions, which must have a plot that house could be placed in accordance with the
Minimal plot

width
23,66 m
length
26,66 m
Dimensions of the front elevation
Dimensions of the front elevation - the dimensions of the front façade of the building along with the retaining wall surfaces excluding windows and doors
15,66 m

Area and dimensions

Usable / net
203,2 / 249,3 m²
Usable: Area of all rooms except for the technical room, garage, utility room, attic. When sizes does not include plaster and wall coverings.
Net area: This is the area of all rooms of the building measured at floor level, taking into account plaster and wall cladding. Does not diminish the floor area of variable height - eg. In the attic. To put it simply - so as to spread in all areas of the carpet on the floor.
Living area
247,0 m²
Living area: Is a surface contour of the exterior walls of the building. For building area is not included: the underground part of the building, ramp car, external stairs, porches, canopies over the entrances, galleries and all floor. But it takes into account eg. Conservatories or other elements of the build.
Garage area
Cubic
782,4 m³
Cubic: The volume of the room, or floor area multiplied by the height of the floor. To calculate the volume of the assumed height measured from the floor - from the bottom floor or to the bottom of the flat roof.
The height of the house
8,35 m
The height of the house - height from ground level to the ridge or attic.
The angle of inclination of the roof
The angle of inclination of the roof - the angle of the roof to the ground.
Roof area
151 m²
Roof area - total roof area with the exception of roof windows.
Minimal plot
23,66 x 26,66 m
 

Technology and construction

Walls
aerated concrete, ceramics, silicates
Ceiling (ground floor)
reinforced concrete
Roof
plate, foil, bituminous
technology
brick

Thermal insulation

heating system
solid fuel, solar panels, ERV, biomass
heating system - Type of heating provided for the project
Primary energy (Ep)
30,2 kWh/m²/year
Primary energy (Ep) - the amount of energy extracted at source and needed to meet the demand for home heating, domestic hot water, air conditioning, mechanical ventilation.
Final energy (Ek)
82 kWh/m²/year
Final energy (Ek) - the amount of energy that must be purchased to ogrzawania home, domestic hot water, mechanical ventilation, and air conditioning. More specifically, it is the energy per 1 m² per year.

WARNING! The energy label NF40 means that the demand for a given building for usable energy does not exceed 40 kWh / m2 year. The project has mechanical ventilation with heat recovery, increased thermal insulation of partitions, solar collectors, efficient ecological heating source and additional solutions eliminating thermal bridges. The project requires adaptation to local conditions so that the governmental program of the National Fund for Environmental Protection and Water Management can be used. The given sizes and dimensions are subject to change due to the design adjustment for the NF40 standard.


By continuing to use this website you agree that we can place cookies and other similar technology on your device, including mobile device, per your agreement with our cookie consent manager. We use information collected from our cookies to provide services, personalize the content, analyze the user behavior and serve offers based on your profile and for the other purposes described in privacy policy to the extent legally permissible in certain jurisdictions. The cookies can also be used by ours Trusted Partners (you can find the list in privacy policy).

The use of cookies is necessary for the website to function properly. If you don't agree to use them, click the "I disagree" button, which will force your browser to leave the website.

I understand